Solution · Net Zero & Energy

Net zero isn't a slogan. It's a meter, a benchmark, and the work in between.

cut the bill, hit the target

Most estates have an EPC certificate that doesn't match the bill. Sensors close that gap — continuous kWh, real-world performance vs design, and the savings that come from heating only the rooms you're using.

What's In It

Three capabilities, one feed.

Continuous metering

Per site and per zone (where sub-metered) — electric, gas, heat. Hourly uplink, daily totals, monthly rollups ready for the report.

Sector benchmarking

Your kWh/m²/yr against the 317-row CIBSE TM46 benchmark library. Top-quartile flags surface where the waste is.

Boiler control included

Where the savings actually happen. Retrofit timeclock control means the boiler stops firing into empty rooms. See /control.

Across surveyed schools: 45% of boiler hours wasted on empty rooms before control was added. The biggest single saving in any estate.

Energy
Sun, 24 May 2026
Live · 47.2 kW electricity · gas heating on · last reading 14:55
Lovelock House · School · All fuels
0kgCO₂e
today

920 kWh electricity + 1,700 kWh gas

Gas heating is 62% of today’s carbon.

Total carbon across all fuels. DEFRA 2026 — electricity 0.207, gas 0.183 kg/kWh.

energy meters · grid factor DEFRA 2026

Day · kW load profile
this period prior
00:0012:00now
Electricity & Gas

Where the carbon comes from.

Two fuels, one carbon total. Gas heats the building; electricity runs everything else.

Electricity38% of carbon
920 kWh

190 kgCO₂e · runs lighting, power, cooling

Gas62% of carbon
1,700 kWh

311 kgCO₂e · space heating & hot water

Gas is 62% of the carbon from 65%of the energy — heating is where the decarbonisation gain is.

Performance vs EPC & DEC

Designed a C — running an E.

EPC rates the design. DEC rates how the building actually runs. The gap is the opportunity.

0kWh/m²/yr

Operational use is running 29% over the design rating.

90-day running rate, all fuels. Operational rating benchmarked to CIBSE TM46 typical school.

0300 kWh/m²/yr
EPC Casset — the designDEC Eoperational — how it runsThe two-band gap is the live opportunity.
Net Zero & Energy — what it looks like in the app
More Than A Dashboard

It doesn’t stop at the screen.

The reading is checked against the rulebook on an orchestration engine. When it’s out of band the job is created, sent to the right person and chased until it’s signed off — and every step is logged. Here’s a real flow for net zero & energy.

ORTRIGGEROKLoad at 02:0031 kW · meter pulseCONDITIONOKBuilding empty?occupancy + holiday calendarCONDITIONOKAbove night baseload?vs this building's normalACTIONOKCut the heatingtimeclock reset · relay offACTIONOKTask to the FMwith the zone and the kWh cost

Rules & flows on an orchestration engine · every action traceable to a line of config

Next Step

Carry this on your estate?

Short call. We’ll scope what a v1 deployment looks like and walk through the standards we can prove the day it goes live.